slider image slider_item_nFEGj9

Laboratory Ice Machines

Shop laboratory ice machines for ice baths, sample transport and reagent cooling. Compare flake and nugget undercounter units (91–440 lb/day) and modular heads.

Filters

Blue promotional graphic with white text reading 'Keep Your Business Running With Reliable Ice Solutions,' smaller descriptive text about ice machines, and a yellow button that says 'Shop Best Sellers.'.
A stainless steel commercial ice machine with a dark gray top and bottom trim, featuring a front vented door and a visible ExpiCyte digital display on the lower left. The brand 'Scotsman' is printed on the top front panel.
A stainless steel commercial ice machine with a dark gray top and bottom trim, featuring a front vented door and a visible ExpiCyte digital display on the lower left. The brand 'Scotsman' is printed on the top front panel.
Best Seller

Scotsman Prodigy Plus NH0422AX-1 Commercial Nugget Ice Machine Head - 375 lb/Day H² Nugget Ice, 22 Inch Air-Cooled 115V

Free Shipping
Regular price $5,051.00
Sale price $5,051.00 Regular price $12,320.00
Unit price
A stainless steel commercial ice machine with a black front panel, vented lower section, and a visible BUNN logo badge, shown on a plain white background.
A stainless steel commercial ice machine with a black front panel, vented lower section, and a visible BUNN logo badge, shown on a plain white background.

Manitowoc UFP0200A Undercounter Flake Ice Maker - 257 lb/Day with 50 lb Bin, Air-Cooled

Free Shipping
Regular price $5,048.00
Sale price $5,048.00 Regular price $11,605.00
Unit price
Front view of the ITV IQN 700 modular nugget ice machine head, rated at up to 714 lb/day.
Front view of the ITV IQN 700 modular nugget ice machine head, rated at up to 714 lb/day.

ITV IQN 700 R290 Commercial Nugget Ice Machine Head - 714 lb/Day, 22 inches Air-Cooled Modular

Free Shipping
Regular price $7,126.50
Sale price $7,126.50 Regular price $14,253.00
Unit price
Front view of ITV IQN 200C undercounter nugget ice machine
Front view of ITV IQN 200C undercounter nugget ice machine

ITV IQN 200C Commercial Nugget Ice Machine - 192 lb/Day, 18 inches Air-Cooled Self Contained

Free Shipping
Regular price $4,550.00
Sale price $4,550.00 Regular price $9,100.00
Unit price
« 1 2
Sort by
  • Featured
  • Most relevant
  • Best selling
  • Alphabetically, A-Z
  • Alphabetically, Z-A
  • Price, low to high
  • Price, high to low
  • Date, old to new
  • Date, new to old

Why labs use flake ice

Lab work needs ice that touches the sample container on every side. Hard cubes leave air gaps and can tip tubes over. Flake ice:

  • Molds around tubes, racks and flasks, so heat transfer is even and fast.
  • Holds samples upright in an ice bucket.
  • Is easy to scoop into buckets of any size.
  • Makes smooth ice baths for chemistry and biology protocols.

Nugget ice is a good second choice: it packs reasonably well, is easy to scoop and suits labs that also want ice for drinks in a break room. Cube ice is the least suitable for bench work.

Ice Packs around tubes Melt rate Best lab use
Flake Excellent Faster Ice buckets, baths, specimen transport
Nugget Good Medium Ice buckets, general cooling, shared break rooms
Cube Poor Slowest Not recommended for bench work

Choosing a format

Situation Format Example machines
One lab or small group Undercounter flake, built-in bin Scotsman UF1415AX-1, UF2020AX-1, Manitowoc UFP0200A
A busy lab suite Large undercounter flake Scotsman UF424AX-1, Manitowoc UFP0350A
A shared floor or core facility Modular flake head on a bin ITV IQF 700, IQF 900, ICETRO IM-0770-AF
A whole building or hospital lab Large flake or nugget head ITV IQF 1200, Scotsman NS1322AX-32

Laboratory ice machines compared

Undercounter (built-in bin)

Model Ice Rated lb/day At 90/70 Bin Width
Scotsman UF0915AX-1 Flake 96 76 36 lb 15 in.
Scotsman UF1415AX-1 Flake 142 107 36 lb 15 in.
ITV IQN 200C Nugget 192 159 44 lb 18.3 in.
Scotsman UF2020AX-1 Flake 216 149 57 lb 20 in.
Manitowoc UFP0200A Flake 257 198 50 lb 19.2 in.
Manitowoc UFP0350A Flake 398 328 60 lb 29.1 in.
Scotsman UF424AX-1 Flake 440 310 80 lb 24 in.

Modular heads (separate bin)

Model Ice Rated lb/day Hot-day output Power
Manitowoc RNP0320A Nugget 308 236 115V
Scotsman NH0422AX-1 H² nugget 375 285 115V
Ice-O-Matic GEM0450A90 Pearl nugget 415 304 115V
ICETRO IM-0770-AF Flake 760 595 115V
ITV IQF 700 Flake 772 635 (90/68) 115V
ITV IQF 900 Flake 860 664 115V
ITV IQF 1200 Flake 1,250 930 220V

Specifications from each product page. The grid also includes more nugget heads and undercounter nugget machines. The Manitowoc UFK, UNK and RNK models ending in AZ are 230V / 50Hz versions for markets with 50Hz power; U.S. labs should choose the UFP, UNP and RNP equivalents.

How much ice does a lab need?

Labs measure ice in buckets, not pounds. Flake ice weighs roughly 30 lb per cubic foot (a common planning figure), so:

Ice bucket Approx. volume Flake ice per fill
Small bench bucket 1 L About 1 lb
Standard ice bucket 4 L About 4 lb
Large pan or tray 9 L About 9-10 lb

Example: a lab with 12 researchers, each filling a 4 L bucket twice a day, uses about 12 x 2 x 4 = 96 lb a day, plus ice baths and transport coolers, so plan about 120 lb. A Scotsman UF1415AX-1 (107 lb at 90/70) is close; a UF2020AX-1 (149 lb) gives headroom. A floor with 60 researchers needs about 500-600 lb a day, which suits an ITV IQF 700 or IQF 900 on a bin.

Placement in a research building

  • Shared machines usually sit in a corridor alcove, equipment room or core facility, so every lab can reach them. Choose a spot with a floor drain.
  • Keep it out of cold rooms unless the manufacturer approves the temperature; most machines need at least 50°F air. Also avoid hot equipment rooms: output falls in heat.
  • Clear the front grille. Many undercounter flake machines, including the Scotsman UF series, are front-breathing.
  • Heat output: undercounter flake machines release about 1,500-3,000 BTU/hr (Scotsman UF0915 and UF424), and large heads more. Check that the room's HVAC can handle it.
  • Power: 115V for most machines here; the ITV IQF 1200 needs 220V.

Lab ice is not sterile or pure water ice

Ice machines make ice from the building's potable water, filtered for taste, sediment and scale. The ice is suitable for cooling sealed containers. It is not sterile, deionized or analytical-grade, so it should not contact samples directly or be used where water purity matters. For those uses, prepare ice from purified water in a laboratory freezer, following your lab's procedures. Dry ice is a different product altogether.

Water treatment and maintenance

  • Filtration: fit a water filter with scale inhibitor sized to the machine. Flake and nugget machines run an auger continuously and are sensitive to scale.
  • Cleaning: clean and sanitize at least every six months, or more often per your facility's biosafety and hygiene rules.
  • Scoops: use a dedicated scoop stored outside the ice. Never fill buckets by dipping them into the bin.
  • Contamination: don't put used buckets, gloves or anything that has been in the lab into the ice bin.

Read our maintenance checklist.

Running costs

From the product pages: Scotsman UF flake machines use 4.20-5.75 kWh per 100 lb and about 12 gallons of water per 100 lb; ITV IQF heads use about 4.4-5.9 kWh. At 150 lb a day and $0.15 per kWh, a UF2020AX-1 costs about $380 a year in electricity. Flake machines use much less water than cube machines.

Universities and procurement

For university and hospital purchasing, list the requirements your facilities team needs: voltage (115V or 220V), drain type, footprint, ice type (flake), daily output at 90°F air / 70°F water, bin size, water connection and warranty terms. We can provide spec sheets for quotes.

One shared machine or several small ones?

One large shared machine A small machine in each lab
Equipment cost Lower per pound of ice Higher per pound
Convenience Researchers walk to the ice room Ice at the bench
Downtime One failure affects the whole floor One failure affects one lab
Utilities One drain, one dedicated circuit A drain and circuit in every lab
Cleaning One machine on a schedule Many machines, easy to miss one

Many research buildings combine both: a modular flake head on a bin in a central ice room for bulk use, plus a small undercounter unit in labs that use ice constantly.

Worked example: a core facility

A genomics core runs sample preparation for 10 labs. Each day it fills about 60 standard 4 L buckets (about 240 lb), keeps two 50 lb transport coolers topped up (about 100 lb) and supplies ice baths for a few protocols (about 40 lb).

  • Total: about 380 lb a day, with most demand in the morning.
  • Machine: an ITV IQF 700 (635 lb at 90/68) or an ICETRO IM-0770-AF (595 lb hot-day) on a storage bin leaves room for growth and for warm summer days.
  • Bin: size it to cover the morning peak, about half the day's use, so roughly 200 lb or more of storage.

The two Manitowoc undercounter models (UFP0200A at 198 lb and UFP0350A at 328 lb hot-day) would struggle at 380 lb, which is why core facilities usually move to a modular head.

Ice for sample transport

Flake ice is the usual choice for moving samples between buildings because it fills the gaps in a cooler and keeps tubes upright.

  • Use sealed, labeled secondary containers inside the cooler so samples never contact the ice directly.
  • Fill coolers from the scoop, not by dipping the cooler into the bin.
  • Don't return used ice to the machine's bin.
  • Follow your institution's biosafety and transport rules for the material you're moving.

Safety around ice machines

  • Slips: flake machines and ice rooms create wet floors. Keep a mat and a floor drain nearby, and clean up spilled ice promptly.
  • Lifting: a full 4 L bucket is light, but transport coolers and 20 lb ice bags are not. Store coolers at a comfortable height.
  • Electrical: keep the machine's dedicated outlet away from where water collects.

Specifying a lab ice machine: what to include

For a facilities request or bid, list:

  • Ice type: flake for bench use, nugget if it also serves a break room.
  • Daily output at 90°F air and 70°F water, with your estimated use and growth margin.
  • Storage: built-in bin size, or a separate bin sized to the morning peak.
  • Footprint and height, including clearance above for service.
  • Utilities: voltage and phase, dedicated circuit, water line size and pressure, drain type and air gap.
  • Water treatment: filter with scale inhibitor and a shut-off valve.
  • Cleaning plan: frequency, who is responsible and how it is recorded.

Hospital and clinical labs

Hospital labs often share ice with nursing units, but their needs differ. Patient areas usually want nugget or cubelet ice for drinking, while the lab wants flake for specimens. Keeping them on separate machines avoids patient-care ice being used for specimens and vice versa, and lets each machine sit where it's used. Specimen ice should be handled under the lab's biosafety procedures, and patient ice under the hospital's infection-prevention policy. See healthcare ice machines.

Common mistakes

  1. Buying a cube machine for bench work. Flake packs around tubes; cubes don't.
  2. Treating machine ice as pure or sterile. It's made from potable water.
  3. Ordering a 50Hz model. Choose UFP, UNP or RNP for U.S. power.
  4. Putting the machine in a hot equipment room. Output drops.
  5. No drain. Flake machines drain meltwater continuously.

Related collections

Frequently Asked Questions

What ice machine is used in laboratories?

Labs most often use flake ice machines, because flake ice molds around tubes, racks and flasks for even cooling. Undercounter flake machines such as the Scotsman UF1415AX-1 or UF2020AX-1 suit a single lab; modular flake heads such as the ITV IQF 700 or IQF 900 suit a shared floor.

Flake vs nugget ice for lab samples: which is better?

Flake is better for ice buckets and baths because it packs tightly around containers and holds them upright. Nugget works well for general cooling and is a good choice if the same machine also supplies a break room.

How much ice does a lab need?

Count buckets. A standard 4 L ice bucket holds about 4 lb of flake ice. A lab with 12 people filling a bucket twice a day uses about 96 lb, so plan about 120 lb with ice baths and transport. A floor of 60 researchers may need 500-600 lb a day.

Is ice machine ice sterile?

No. Ice machines make ice from filtered potable water. It is suitable for cooling sealed containers, but it is not sterile, deionized or analytical-grade, so it should not contact samples directly or be used where water purity matters.

Where should a lab ice machine be installed?

Install it in a shared, accessible spot such as a corridor alcove or equipment room, near a floor drain, with air temperature within the machine's operating range (typically 50-100°F). Avoid cold rooms and hot equipment rooms, and keep the front grille clear.

Should a research building have one large ice machine or several small ones?

Many buildings combine both. A modular flake head on a bin in a central ice room supplies bulk ice at the lowest cost per pound, while small undercounter machines serve labs that use ice all day. One shared machine is cheaper but creates a single point of failure.

Can a lab use a 50Hz ice machine?

Only where the building supplies 50Hz power. The Manitowoc UFK, UNK and RNK models ending in AZ are 230V / 50Hz versions for those markets. U.S. labs run on 60Hz, so choose the UFP, UNP or RNP equivalents.

How often should a lab ice machine be cleaned?

Clean and sanitize it at least every six months, following the manufacturer’s procedure, and more often if your facility’s biosafety or hygiene rules require it. Change the water filter on schedule and keep a log of cleaning dates.