{"product_id":"srcp035a-1su","title":"Scotsman SRCP035A-1SU Brilliance 15-Inch Undercounter Gourmet Ice Maker - 35 lb\/Day with 26 lb Bin, Built-In Pump, Panel-Ready","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Scotsman SRCP035A-1SU combines the Brilliance SRC035 clear gourmet ice format with a cabinet-ready unfinished front and built-in drain pump. The model is aimed at indoor kitchens where the ice maker should visually blend with neighboring cabinets and a gravity-only drain route would be inconvenient. Scotsman rates SRCP035A-1SU at 35 lb per 24 hours with 70°F air and 50°F water, and 16 lb per 24 hours with 90°F air and 70°F water. A self-contained, insulated 26 lb bin keeps ice available to scoop; it does not mean the bin is a freezer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIts 26 lb integrated bin is useful for serving from stored ice, while production replenishes that bin over time. A pump solves a drainage layout problem, not the pace of ice making. For continuous hosting, consider the published warmer-condition output as carefully as the 35 lb\/day headline.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCompared with SRCG035A-1SU, the defining difference is the integrated pump. This configuration is well suited when both a custom exterior finish and pumped drainage are requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe front is unfinished for a locally sourced cabinet panel or the compatible Scotsman KDFS stainless-front kit. Follow the manufacturer drawing for panel, door-swing and handle clearances before fabrication.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eClear Gourmet Cube Ice made at up to 35 lb\/day under 70°F\/50°F rated conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e16 lb\/day at the warmer 90°F air\/70°F water condition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e26 lb self-contained, insulated ice storage bin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAir-cooled, front-ventilated cabinet with R290 refrigerant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBuilt-in drain pump with 10 ft drain tube listed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eUnfinished door front suitable for a separately sourced custom decorative panel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFor indoor installation only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eField-reversible door (confirm surrounding clearance on the installation drawing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCustom-front indoor kitchen with drain routing that calls for a pump\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eResidential wet bar where floor-drain placement is limited\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBuyer who values integrated storage and an understated built-in look\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFull Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" align=\"center\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"257\"\u003e\n\u003ccol width=\"376\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eScotsman\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrilliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eExact model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSRCP035A-1SU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMachine type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eResidential undercounter self-contained ice maker with built-in bin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIce type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClear Gourmet Cube Ice\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDaily production, 70°F air \/ 50°F water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e35 lb per 24 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDaily production, 90°F air \/ 70°F water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e16 lb per 24 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStorage capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e26 lb insulated bin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCabinet dimensions (W × D × H)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e14.875 × 22 × 33.375 in., cabinet without legs\/handle projection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNominal width class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15-inch undercounter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCondenser \/ cooling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAir-cooled, self-contained\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRefrigerant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eR290\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElectrical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e115 V \/ 60 Hz \/ 1 phase; dedicated 15 A circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRated current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e5 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDrain type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBuilt-in drain pump\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCabinet \/ door finish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUnfinished \/ custom-panel-ready\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIndoor only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAmbient operating air range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e50°F to 100°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWater temperature range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e40-100°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWater pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 to 80 psig\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eShipping weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e118 lb (manufacturer figure)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1 year parts and labor; 5 years total compressor parts (compressor labor after year 1 not covered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eScotsman residential DRC and SRC models carry 1 year of parts and labor coverage; compressor parts are covered for 5 years total, with compressor labor after year 1 excluded. Registration, exclusions, eligible locations and service terms are governed by Scotsman's current warranty statement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eInstallation and Maintenance Notes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eA built-in drain pump is included; the manufacturer lists 10 feet of pump drain tube. The installation still requires an approved drain destination and the routing described in the owner manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThis family is indoor-only. Install it in a conditioned location meeting the 50°F to 100°F ambient range; do not market it for outdoor kitchens.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eProvide potable water within 40-100°F and 20-80 psig; check the manual for filtration, connection sizing, sanitation and local code requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eUse a dedicated 115 V \/ 60 Hz \/ single-phase, 15 A electrical circuit. Confirm clearance for the reversible door and front airflow. Cabinet-only dimensions exclude some projections and installation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eClean and descale as directed in the owner manual; an insulated bin is not mechanically refrigerated, so drainage and regular cleaning matter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- SEO_SCHEMA_START --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Scotsman SRCP035A-1SU 35 lb\/Day Gourmet Ice Maker with Drain Pump\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"ICE MAKER SUPPLY\"\n  },\n  \"aggregateRating\": {\n    \"@type\": \"AggregateRating\",\n    \"ratingValue\": 5,\n    \"ratingCount\": 21,\n    \"bestRating\": 5,\n    \"worstRating\": 4\n  }\n}\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much ice does the Scotsman SRCP035A-1SU make per day?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Scotsman lists 35 lb\/day at 70°F air and 50°F water, or 16 lb\/day at 90°F air and 70°F water. Actual output varies with air, water and installation conditions.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much ice can the SRCP035A-1SU store?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The built-in insulated storage bin holds up to 26 lb. Daily ice production and bin storage are different ratings; stored ice can gradually melt and drain away.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the SRCP035A-1SU need a drain pump?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This model includes a built-in drain pump. The installer must verify the allowable discharge run and an approved drain connection.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the SRCP035A-1SU be installed outdoors?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Scotsman labels this product family indoor-only. For a sheltered outdoor bar, review SRC065 gourmet or SRN110 nugget options instead.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is the SRCP035A-1SU panel-ready?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. This -1SU model has an unfinished front intended for a separately supplied cabinet panel or compatible Scotsman front kit; confirm hardware and finished dimensions.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What should the cabinet installer check?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Measure the required custom front panel, handle projection and reversible door-swing clearance against Scotsman drawings before cabinet construction.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What electrical connection does the SRCP035A-1SU require?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The manufacturer's specification lists 115 V, 60 Hz, single-phase service and a dedicated 15 A circuit; the rated current is 5 A. Have the installer verify the rating plate and applicable electrical code.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What warranty applies to SRCP035A-1SU?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Scotsman lists one year parts and labor, plus compressor-parts coverage through year five. Compressor labor beyond the first year is not included; registration and other terms apply.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c!-- SEO_SCHEMA_END --\u003e\n","brand":"Scotsman","offers":[{"title":"Default Title","offer_id":68273469096047,"sku":null,"price":3579.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/3857\/1375\/files\/SRCP035A-1SU-DoorClosedwithKDFS.webp?v=1794236744","url":"https:\/\/icemakersupply.com\/products\/srcp035a-1su","provider":"ICE MAKER SUPPLY","version":"1.0","type":"link"}